Autor: |
João Paulo Mendes Tribst, Renato Sussumu Nishioka, Dimas Renó de Lima, Vinícius Anéas Rodrigues, Leandro Ruivo de Santis |
Rok vydání: |
2017 |
Předmět: |
|
Zdroj: |
Brazilian Dental Science. 20:32-39 |
ISSN: |
2178-6011 |
DOI: |
10.14295/bds.2017.v20i1.1311 |
Popis: |
Objective: This in vitro study was to evaluate micro-strains around of implant, under the influence of angulations and vertical misfit in three-element implant-supported fixed partial dentures during axial loading by using strain gauge analysis. Materials and Methods: Three external hexagon implants with straight configuration and three external hexagon implants with angled (17°) configuration were inserted into two polyurethane blocks. To measure micro-strain, four strain gauges were bonded onto the surface of each block. Plastic copings were adapted to a standard wax pattern and cast. An axial load of 30 kgf was applied on the center of each implant for 10 seconds, using a load application device. The vertical misfit was measured at six different points by using a stereo microscope with 100-X magnification. Results: The results showed that the values for different implant angulations were significant (P= 0.0086). The Pearson’s correlation test between micro-strain and vertical misfit revealed no correlation between angled configuration (P= 0.891) and straight configuration (P= 0.568). Conclusion: The micro strain was higher for angled implants; no correlation was found between the vertical misfit and the micro strain values. |