Popis: Self-healing is an interesting property of metallized capacitors. contract resistance is importance to self healing. In the paper contract resistance is calculated with different diameters of hole and different thickness of metal layer. The larger is radius of hole, the less is contract resistance. The thicker is metal layer, the less is contract resistance.