Popis: |
Ti-Nb-Zr-Ta alloys represent a new generation of biomaterials with possible applications in the orthopedic field, being developed in order to eliminate the negative aspects of the current orthopedic biomaterials, which consist mainly in a low biocompatibility with human tissues and high values of modulus of elasticity compared to the human bone. This paper presents a comparative study of new titanium alloys, corresponding to the Ti-Nb-Zr-Ta system: Ti-21Nb-6Zr-15Ta and Ti-25Nb-10Zr-8Ta, which were analyzed by scanning electron microscopy, X-ray diffraction and microindentation. The both alloys are classified as near-β alloys. The addition of alloying elements such as Ta, Nb and Zr represents a good solution for lowering modulus of elasticity, which is an important factor for reducing bone resorption and therefore for preventing implant failure. |