137Cs/137mBa radioisotope generator based on 6-tungstocerate(IV) column matrix
Autor: | M. Mostafa, A. A. Abdel Fattah, M. A. El-Amir, H. El-Said, Hisham M. Aly, M. A. El-Absy |
---|---|
Rok vydání: | 2005 |
Předmět: |
Column vector
Chromatography Chemistry Atomic battery Elution Health Toxicology and Mutagenesis Gel matrix Public Health Environmental and Occupational Health Pollution Analytical Chemistry Volumetric flow rate Column chromatography Nuclear Energy and Engineering Radiology Nuclear Medicine and imaging Chromatographic column Spectroscopy |
Zdroj: | Journal of Radioanalytical and Nuclear Chemistry. 267:161-167 |
ISSN: | 1588-2780 0236-5731 |
DOI: | 10.1007/s10967-006-0023-y |
Popis: | Barium-137m radioisotope generator of the chromatographic column elution mode based on loading 1.5 g 6-tungstocerate(IV) gel matrix with ~54 kBq of fission-produced 137 Cs is described. The elution performance of the generated 137m Ba radionuclide was investigated as a function of chemical composition of the eluent, flow rate, elution frequency, and age of the generator system. At comparable conditions, 137m Ba eluates with 0.9% NaCl–0.1M HCl eluent had higher elution yields and radionuclidic purity than with 0.1M NH4Cl–0.1M HCl eluent. The generator has been repeatedly eluted for 311 days by passing 4810 ml of the saline eluent (10 ml × 481 elution operations) at a flow rate of 3.0 ml/min. Barium-137m eluates of high and reproducible elution yields, chemical and radionuclidic purities of (8 99.99%) were obtained. |
Databáze: | OpenAIRE |
Externí odkaz: |