TITANIUM GETTER PUMP FOR THE TORE SUPRA NEUTRAL BEAM LINES

Autor: J. Druaux, Z. Sledziewski
Rok vydání: 1986
Předmět:
DOI: 10.1016/b978-1-4832-8376-0.50062-0
Popis: Titanium getter pumps will be used for the pumping of H 2 or D 2 gas on the neutral beam lines for TORE SUPRA. This choice is based on several reasons. Firstly, the pumping speed of these pumps is comparable to the speed of geometrically equivalent cryopumps while the costs of operation of the pump are considerably reduced. Furthermore, it has been found that at a temperature of 350° to 400deg;C the Ti layers can be outgassed, so the Titanium can be used with a very high efficiency.