Investigation of the losses of the auxiliary system and torsional vibrations during the parallel operation of Severo-Zapadnaya TPP on two power systems
Jazyk: | ruština |
---|---|
Rok vydání: | 2021 |
Předmět: |
кÑÑÑилÑнÑе колебаниÑ
наÑÑÑойка ÑегÑлÑÑоÑов возбÑÐ¶Ð´ÐµÐ½Ð¸Ñ ÑлекÑÑоÑнеÑгеÑиÑеÑкие ÑиÑÑÐµÐ¼Ñ ÐлекÑÑиÑеÑкие ÑÑанÑии поÑеÑи ÑобÑÑвеннÑÑ Ð½Ñжд ÐÑÑиÑлиÑелÑнÑе маÑÐ¸Ð½Ñ ÑлекÑÑоннÑе |
DOI: | 10.18720/spbpu/3/2021/vr/vr21-1477 |
Popis: | ЦелÑÑ Ð´Ð°Ð½Ð½Ð¾Ð¹ ÑабоÑÑ ÑвлÑеÑÑÑ Ñнижение поÑеÑÑ Ð² ÑиÑÑеме ÑобÑÑвеннÑÑ Ð½Ñжд СевеÑо-Ðападной ТÐЦ, а Ñакже опÑимизаÑÐ¸Ñ Ð¿ÑоÑеÑÑа пеÑеклÑÑÐµÐ½Ð¸Ñ Ð¿ÐµÑвого ÑнеÑгоблока СевеÑо-Ðападной ТÐЦ из ÑнеÑгоÑиÑÑÐµÐ¼Ñ Ð¤Ð¸Ð½Ð»Ñндии в ÑнеÑгоÑиÑÑÐµÐ¼Ñ Ð Ð¾ÑÑии. Ðо даннÑм, полÑÑеннÑм Ñ Ð¡ÐµÐ²ÐµÑо-Ðападной ТÐЦ, бÑла ÑмоделиÑована ÑÑ ÐµÐ¼Ð° ТÐЦ в пÑогÑаммном комплекÑе RastrWin. Ð ÑезÑлÑÑаÑе бÑла пÑоведена опÑимизаÑÐ¸Ñ Ñежимов ÑабоÑÑ Ð¡Ð Ð¿ÑÑÑм Ð¸Ð·Ð¼ÐµÐ½ÐµÐ½Ð¸Ñ ÑиÑла виÑков ÑÑанÑÑоÑмаÑоÑа ТСÐ, Ñ Ð¿Ð¾Ð¼Ð¾ÑÑÑ ÑегÑлиÑÐ¾Ð²Ð°Ð½Ð¸Ñ Ð¿Ð¾Ð´ нагÑÑзкой, и бÑла пÑоведена ÑкономиÑеÑÐºÐ°Ñ Ð¾Ñенка полÑÑеннÑÑ ÑезÑлÑÑаÑов. СледÑÑÑим ÑÑапом ÑабоÑÑ Ð±Ñла ÑазÑабоÑка ÑпÑоÑенной модели ÑÑ ÐµÐ¼Ñ Ð²ÑдаÑи моÑноÑÑи СевеÑо-Ðападной ТÐЦ в ÑоÑÑийÑкÑÑ Ð¸ ÑинÑкÑÑ ÑнеÑгоÑиÑÑÐµÐ¼Ñ Ð² пÑогÑамме MATLAB/Simulink. ÐÐ»Ñ Ð¾Ð¿ÑÐµÐ´ÐµÐ»ÐµÐ½Ð¸Ñ Ð¿ÑавдоподобноÑÑи модели из пÑогÑÐ°Ð¼Ð¼Ñ MATLAB/Simulink, бÑло ÑмоделиÑовано ÑÑÑÑ Ñазное коÑоÑкое замÑкание, ÑезÑлÑÑаÑÑ Ð¿Ð¾Ð»ÑÑеннÑÑ ÐºÑивÑÑ ÑÑавнивалиÑÑ Ñ ÑезÑлÑÑаÑами иÑÑледований ÐÐÐÐТ. ÐолÑÑеннÑе гÑаÑики имеÑÑ ÑÑ Ð¾Ð¶Ð¸Ð¹ Ñ Ð°ÑакÑÐµÑ Ñ ÑезÑлÑÑаÑами ÑаÑÑеÑов, полÑÑеннÑми Ñ ÐÐÐÐТ, ÑÑо говоÑÐ¸Ñ Ð¾ возможноÑÑи иÑполÑÐ·Ð¾Ð²Ð°Ð½Ð¸Ñ Ð¼Ð¾Ð´ÐµÐ»Ð¸ в данной ÑабоÑе Ð´Ð»Ñ Ð´Ð°Ð»ÑнейÑÐ¸Ñ Ð¸ÑÑледований. Ð ÑиналÑной ÑаÑÑи ÑабоÑÑ Ð±Ñли вÑÑÐ²Ð»ÐµÐ½Ñ ÑаÑÑоÑÑ ÐºÑÑÑилÑнÑÑ ÐºÐ¾Ð»ÐµÐ±Ð°Ð½Ð¸Ð¹ Ñ Ð¿Ð¾Ð¼Ð¾ÑÑÑ Ð±ÑÑÑÑого пÑеобÑÐ°Ð·Ð¾Ð²Ð°Ð½Ð¸Ñ Ð¤ÑÑÑе и пÑоизведена опÑимизаÑÐ¸Ñ Ñ Ð¿Ð¾Ð¼Ð¾ÑÑÑ Ð½Ð°ÑÑÑойки ÑегÑлÑÑоÑов возбÑждениÑ. The aim of this work is to reduce losses in the auxiliary system of the North-West CHPP, as well as to optimize the process of switching the first power unit of the North-West CHPP from the Finnish power system to the Russian power system. According to the data obtained from the North-West CHPP, the CHPP scheme was modeled in the RastrWin software package. As a result, the optimization of the MV operating modes was carried out by changing the number of turns of the TSN transformer, with the help of regulation under load, and an economic assessment of the results was carried out. The next stage of the work was the development of a simplified model of the scheme for the power delivery of the North-West CHPP to the Russian and Finnish power systems in the MATLAB / Simulink program, taking into account the torsional vibrations of the shafting. To determine the plausibility of the model from the MATLAB / Simulink program, a comparison was made with the results of the NIIPT research. The resulting graphs are similar in nature to the results of calculations obtained from NIIPT, which indicates the possibility of using the model in this work for further research. |
Databáze: | OpenAIRE |
Externí odkaz: |