Popis: A pilot-plant-scale study of combined sulfur dioxide/nitrogen oxides (SO2/NOx) removal has been performed by the Dravo Lime Company at the Cincinnati Gas and Electric Company's Miami Fort Station in North Bend, Ohio. This study used Dravo's patented Thiosorbic® lime process along with Argonne National Laboratory's (ANL's) patented process for combined SO2/NOx removal using the chelate ferrous·ethylenediaminetetraacetate (Fe·EDTA). For approximately nine months, scrubbing tests were carried out, and waste samples were collected. Waste testing at ANL involved two types of long-term chemical stability experiments. In one test, the gas-phase composition above several different samples was studied by mass spectrometry over 22 months. Unexpectedly, production of carbon dioxide and hydrogen sulfide was observed in some of the samples. The other experiment involved solid-phase leaching. Samples were stored for up to 14 months before leaching. Each leachate was tested for total Kjeldahl nitrogen and for the nitrogen-containing ions nitrite, nitrate, and ammonium. Significant amounts of ammonium ions were found in two of the samples. Total leachable nitrogen was found to stabilize after about the first 7 months of storage.