Autor: |
I. Bikit, T. Nemes, D. Mrdja, S. Forkapic, Matko Milin, Tamara Niksic, Suzana Szilner, Dario Vretenar |
Rok vydání: |
2009 |
Předmět: |
|
Zdroj: |
AIP Conference Proceedings. |
DOI: |
10.1063/1.3232146 |
Popis: |
In the present paper the activity of 60Co source was measured using the full absorption, sum and random coincidences (pile up) peaks and the total spectrum area in the gamma spectra. By the exact treatment of the chance coincidence and pile‐up events, surprisingly good results were obtained. With the source on the detector end‐cap (when the angular correlation effects are negligible), this simple method yields absolute activity values deviating from the reference activity for about 1 percent. |