Popis: |
Objective To evaluate the effects of screw type (mono- [M] versus bicortical [B]), number, and position on torsional stability of String of Pearls (SOP) locking plate constructs. Study Design In vitro mechanical study. Methods SOP plates (n = 32) were applied to bone models and divided into 8 groups named according to screw type (M or B) and position in each fragment relative to the fracture gap starting at the outermost plate hole. Positive and negative controls were MMM and BBB, respectively. Specimens were non-destructively tested in torsion. Compliance and angular deformation were statistically compared (P |