Safety Analyses of VVER-1200/V491 reactor for longterm station blackout along with small LOCAs

Autor: Thi Hoa Bui, Tan Hung Hoang, Minh Giang Hoang
Rok vydání: 2016
Předmět:
Zdroj: Nuclear Science and Technology. 6:8-17
ISSN: 1810-5408
Popis: Performance of Passive Heat Removal through Steam Generator (PHRS-SG) of VVER-1200/V491 reactor presented in Safety Analysis Report for Ninh Thuan 1 shows that in case of long term station black out (SBO), VVER-1200/V491 reactor can be cooldown and remained in safety mode at least 24 hours based on PHRS-SG performance. Anyway, long term station blackout along with small break in main coolant pipe of VVER-1200/V491 is assumed to be happening as an extension design condition that needs to be investigated. This study focuses on investigation of SBO along with different size of small break of LOCAs with expectation of finding the range of break size that the reactor is still kept in safety mode during 24 hours. During the investigation, some indicators for fuel damage such as the timing of HA1 actuation or mass of coolant inventory discharged are introduced as necessary information contributed to Severe Accident Management Guideline (SAMG).
Databáze: OpenAIRE