Estimating the uncertainty of binary test results to assess their compliance with regulatory limits

Autor: Itziar Ruisánchez, F.X. Rius, A. Pulido, Ricard Boqué
Rok vydání: 2002
Předmět:
Zdroj: Analytica Chimica Acta. 455:267-275
ISSN: 0003-2670
DOI: 10.1016/s0003-2670(01)01604-x
Popis: A procedure to calculate the uncertainty associated to a binary response, of the type yes/no, originated from an instrumental screening system, is described. Useful equations have been developed based on statistical intervals, and their validation were performed with standard commercial solution. It was applied to a differential pulse anodic stripping voltammetry (DPASV) screening system to analyse tap water, specifically, for determining Pb 2+ and Cd 2+ above the UE legislation limits, 10 and 5 μg/l, respectively. A cut-off value from the responses of the calibration samples is calculated and compared with the responses obtained for unknown samples. From this comparison, we will be able to take a compliance yes/no decision, with an alpha probability of committing a type I error. Another parameter, r screening , is calculated in order to compare different methods for the same screening application.