Squirrel cage induction motor scalar control constant V/F analysis

Autor: Mohd Badril Nor Shah, Khalil Azha Mohd Annuar, Sahazati Md. Rozali, Mohd Razali Mohamad Sapiee, Rozilawati Mohd Nor, M. S. M. Azali
Rok vydání: 2019
Předmět:
Zdroj: TELKOMNIKA (Telecommunication Computing Electronics and Control). 17:417
ISSN: 2302-9293
1693-6930
Popis: In constant V/f control technique it is assume that the stator resistance and leakage inductance drops are negligible, especially at high speed and small load. In other words, the back emf is comparatively large at high speed and hence these voltage drops can be neglected. By maintaining constant V/f, constant Eg/f and hence constant air-gap flux is assumed. This assumption is however invalid at low speeds since a significant voltage drop appears across the stator impedance. The terminal voltage, V no longer approximates  ag. By using MATLAB Simulink, the open-loop constant V/f is simulated. It is shown that the performance of the drive deteriorates at low speeds. The improvement in the performance by applying voltage boost is shown and discussed.
Databáze: OpenAIRE