Combined motion blur and partial volume correction for computer aided diagnosis of pulmonary nodules in PET/CT
Autor: | Ralph Buchert, Timo Paulus, Rafael Wiemker, Sven Kabus, Susanne Klutmann, Ivayla Apostolova, Thomas Bülow |
---|---|
Rok vydání: | 2008 |
Předmět: |
Solitary pulmonary nodule
medicine.medical_specialty PET-CT business.industry Partial volume correction Partial Volume Averaging Motion blur Biomedical Engineering Partial volume Health Informatics General Medicine medicine.disease Computer Graphics and Computer-Aided Design Computer Science Applications Computer-aided diagnosis medicine Radiology Nuclear Medicine and imaging Surgery Computer Vision and Pattern Recognition Radiology Differential diagnosis business Nuclear medicine |
Zdroj: | International Journal of Computer Assisted Radiology and Surgery. 3:105-113 |
ISSN: | 1861-6429 1861-6410 |
DOI: | 10.1007/s11548-008-0212-y |
Popis: | Objective We present an automated scheme to correct PET max-uptake-values of small to medium-sized pulmonary nodules for motion blur and partial volume averaging. Both effects cause significant underestimation of PET max-uptake-values, particularly in nodules below 25 mm diameter, but nodules up to 75 mm might be affected. This compromises the power of PET for the differential diagnosis of such nodules, in particular benign versus malignant. Thus, correcting PET max-uptake-values has the potential to improve the classification of PET-positive pulmonary nodules. |