P–153 Comparison outcome of vitrified human embryos stored in vapor phase liquid nitrogen (LN2) and direct LN2
Autor: | E J Yu, K A Lee, M Y Shiin, M J Kim, J H Lee, H S Choi, M K Koong, Y J Hur, R Kim, E H Moon, G Y Song, E A Park, H S Kim, K Y Kang, J Y Lee |
---|---|
Rok vydání: | 2021 |
Předmět: | |
Zdroj: | Human Reproduction. 36 |
ISSN: | 1460-2350 0268-1161 |
DOI: | 10.1093/humrep/deab130.152 |
Popis: | Study question Is vapor cryopreserved LN2 storage beneficial for clinical outcomes of vitrified human embryos that are frozen compared to vitrified human embryos having direct contact with LN2. Summary answer There are no significant differences compared to clinical outcomes of human embryos stored in LN2 vapor and direct store in LN2. What is known already There has been concerned about potential cross-contamination and biohazard issues of embryos for long term storage using direct LN2. This study aimed to compare clinical outcomes of human embryos transfer between vapor phase and liquid LN2. Study design, size, duration The embryo has undergone vitrification for long term storage with vapor or direct contact in LN2. After the thawing of the embryo, we checked on the survival rates. We transferred only one or two embryos per patient and kept analyzing the implantation and pregnancy rates Participants/materials, setting, methods This retrospective study was carried out from January 2018 to December 2019 with 3272cycles 4713embryos; vitrified for long term storage in vapor phase or direct contact with LN2. We compared the clinical outcomes of frozen embryo transfer cycles using vitrified for long term storage in vapor phase and direct contact with LN2. Clinical outcomes monitored were embryo survival, subsequent implantation and pregnancy after single or double embryo transfer Main results and the role of chance A total of 4713 fertilized human embryos are vitrified and then stored in LN2 vapor (n = 2520 cycles) or direct contact LN2 (n = 752 cycles). The study showed that the blastocyst stored in vapor able to retain full development. Survival was 97.8% (vapor) and 97.6% (direct contact LN2), and the vapor storage of human embryos had no significant difference in survival rates after a long term storage. For single blastocyst transfer, pregnancy and implantation rates were 51.5%, 52.4% in vapor, 54.6%, 54.9% in direct LN2; respectively (p=NS). In double blastocyst transfer, the pregnancy and implantation rates were 61.8%, 42.0% in vapor and 64.7%, 44.5% in direct LN2; respectively (p=NS). There were also no significant differences between two groups. Limitations, reasons for caution The study showed that the blastocyst stored in vapor can retain full development. A vapor storage system thus is safe and effective for long term vapor storage of vitrified human embryos.Within the limits of this study, there was no detection of an adverse effect of vapor storage. Wider implications of the findings: Vapor storage systems thus represent a useful alternative for safe and effective long-term storage of vitrified human embryos that can avoid cross contamination chances from having direct contact with LN2. Trial registration number Not applicable |
Databáze: | OpenAIRE |
Externí odkaz: |