Popis: The article analyses the influence of the geometry of the downflow and suction lines and perforated baffle on the even flow of the working fluid in the tank of the hydraulic system. During the tests, more attention was paid to identifying the influence of the shape of wires on the phenomena connected with the flow of the fluid in the tank. We considered typical, and recommended by producers of the elements and hydraulic systems, construction forms of pipes introduced vertically into the tank, and comparing them to the pipes cut at a right angle. Since for simulation testing only one construction form was adopted, in this respect the results are only basic. Analyzing the results of simulation, it has been observed that the evenly perforated baffle does not bear significant influence on the equal distribution of fluid flow in the tank.