Popis: |
With different fine aggregate, gradation type, oil stone ratio, asphalt type specimen molding and molding method and calculate the porosity of the specimen. The experimental results show that the using basalt coarse aggregate and fine aggregate forming specimen, specimen porosity significantly larger, all are beyond the scope of regulatory requirements; If using basalt coarse aggregate and limestone fine aggregate forming specimens, specimen porosity is small, both meet regulatory requirements. The main reason is basalt fines aggregate bulk volume density is too large and not easily compacted. Recommendation: we’d better use of basalt coarse aggregate and limestone fine aggregate forming specimen, try to avoid using basalt aggregate thickness of molded specimen. If the region lacks limestone fines, we should detect the special type of basalt fine aggregate firstly. If the indicators of basalt fines are in line with the requirement, you can use, if the indicators do not meet regulatory requirement, you can not use. |