Diferenciação entre cisto simples e hemangioma hepático utilizando seqüência de ressonância magnética ponderada em T2 com técnica gradiente-eco (B-FFE) Differentiation between simple cyst and hepatic hemangioma utilizing T2-weighted magnetic resonance imaging with gradient-echo (b-FFE) technique

Autor: Carolina Valente Burim, Luiz Pecci Neto, Fabiola Goda Torlai, Dario Ariel Tiferes, Giuseppe D'Ippolito
Jazyk: angličtina
Rok vydání: 2008
Předmět:
Zdroj: Radiologia Brasileira, Vol 41, Iss 6, Pp 355-360 (2008)
ISSN: 1678-7099
0100-3984
Popis: OBJETIVO: Estabelecer o valor das seqüências ponderadas em T2 para diferenciar cistos simples de hemangiomas hepáticos. MATERIAIS E MÉTODOS: Estudo prospectivo, observacional, transversal e duplo-cego em 52 pacientes com 91 lesões hepáticas (34 cistos simples e 57 hemangiomas) submetidos a ressonância magnética de abdome. A análise conjunta de todas as seqüências realizadas foi considerada o padrão-ouro. Dois observadores independentes avaliaram, subjetivamente, as seqüências TSE com TE longo e B-FFE, procurando diferenciar cistos de hemangiomas. Foram calculadas a eficácia das seqüências e a concordância interobservador e intra-observador por meio do teste kappa (κ) (p < 0,05*). RESULTADOS: As dimensões dos cistos variaram entre 0,5 e 6,5 cm (média de 1,89 cm) e as dos hemangiomas, entre 0,8 e 11 cm (média de 2,62 cm). A concordância entre a avaliação da seqüência com TE longo e o padrão-ouro foi insignificante (κ: 0,00-0,10). A concordância entre a avaliação da seqüência B-FFE e o padrão-ouro variou de substancial (κ: 0,62-0,71) a quase perfeita (κ: 0,86) para ambos os examinadores. A concordância interobservador e intra-observador para a seqüência B-FFE variou entre substancial (κ: 0,62-0,70) e quase perfeita (κ: 0,85-0,91). CONCLUSÃO: A técnica B-FFE apresenta eficácia e reprodutibilidade elevadas na diferenciação de cistos e hemangiomas.OBJECTIVE: To establish the role of MRI T2-weighted sequences in the differentiation between simple cysts and hepatic hemangiomas. MATERIALS AND METHODS: A double-blinded, prospective, observational, cross-sectional study evaluated 52 patients with 91 hepatic lesions (34 simple cysts and 57 hemangiomas) submitted to abdominal magnetic resonance imaging. The combined analysis of all sequences was considered as the golden-standard. TSE sequences with long echo trains and b-FFE sequences were subjectively analyzed by two independent observers for differentiating cysts from hemangiomas. The kappa test (κ) was utilized in the analysis of the methods accuracy and inter- and intra-observer agreement (p < 0.05*). RESULTS: Cysts and hemangiomas dimensions ranged respectively between 0.5 and 6.5 cm (mean = 1.89 cm), and 0.8 and 11 cm (mean = 2.62 cm). The analysis of the sequences with long-TE and the golden-standard demonstrated a non-statistically significant agreement (κ: 0.00-0.10). The agreement between the evaluation of the b-FFE sequence and the golden-standard ranged from substantial (κ: 0.62-0.71) to almost perfect (κ: 0.86) for both observers. The inter- and intra-observer agreement for the b-FFE sequence ranged from substantial (κ: 0.62-0.70) to almost perfect (κ: 0.85-0.91). CONCLUSION: T2-weighted images acquired with the b-FFE technique present a high accuracy and reproducibility in the differentiation between cysts and hepatic hemangiomas.
Databáze: OpenAIRE