Numerička i eksperimentalna analiza čvrstoće konstrukcije plameno-dimnocijevnog kotla
Autor: | Gaćeša, Branka, Vesna, Milošević-Mitić, Maneski, Taško, Kozak, Dražan, Sertić, Josip |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2011 |
Předmět: | |
Zdroj: | Tehnički vjesnik Volume 18 Issue 2 |
ISSN: | 1848-6339 1330-3651 |
Popis: | Norme kao što su EN 12952-3 i EN 12953-3 obrađuju problematiku proračuna tlačnog dijela kotla, ali bez mehaničkoga utjecaja toplinskih deformacija koje su često puta od vitalnog značaja za integritet kotlovske konstrukcije. Primjena MKE kod projektiranja kotlova u EN se predlaže kod proračuna svih komponenti koje norma ne pokriva. Na ovaj način se proračun utjecaja toplinskih naprezanja ostavlja na slobodnu volju projektanta i tehničkog inspektorata koji nadzire i odobrava stavljanje kotla u rad. U ovom je radu pokazano da je utjecaj toplinskih naprezanja velik i da se mora uzeti u obzir pri projektiranju i procjeni vijeka trajanja kotlovskih konstrukcija. Pokazano je da je za konstrukciju kotla najbolje, prije puštanja u rad, izraditi numeričko eksperimentalnu dijagnostiku. Prvo se eksperimentalno mora potvrditi numerički model, a zatim se on može koristiti za razmatranje različitih parametara dijagnostike čvrstoće kao što su raspodjela membranskih i savojnih naprezanja po podstrukturama i raspodjela energije deformiranja. Oni najbolje ukazuju na uzroke nedovoljno dobrog ponašanja konstukcije. Također se predlaže uvijek izrada dinamičkog proračuna vlastite frekvencije vibriranja. Norms, such as EN 12952-3 and EN 12953-3 handle the issues concerned with calculation of the pressurized boiler components, not however considering the influences of thermal strains that are often of vital importance for the integrity of boiler's construction. Application of FEM in boiler design in EN is suggested in calculating all components that are not covered by the norm. In this way, the calculation of thermal stress is left to the free will of designer and technical inspectorate which supervises and approves placement of a boiler into operation. This paper demonstrates that the influence of thermal stresses is great and that it must be taken into consideration when the boiler's construction is designed and its working life evaluated. It is shown that for every construction a numerical-experimental behaviour diagnostics should be conducted prior to putting it into operation. First, a numerical model must be experimentally verified and then it can be used in considering different parameters of strength diagnostics, such as distribution of membrane and bending stresses for substructures, and distribution of deformation energy. They indicate, in an optimal way, root causes of insufficiently good behaviour of the construction. Also, a dynamical calculation of natural oscillations should always be suggested. |
Databáze: | OpenAIRE |
Externí odkaz: |