Ordonnancement et Allocation Dynamique de Ressources pour des Infrastructures Hétérogènes à Consommation Energétique Proportionnelle

Autor: Villebonnet, Violaine
Přispěvatelé: Laboratoire de l'Informatique du Parallélisme (LIP), École normale supérieure de Lyon (ENS de Lyon)-Université Claude Bernard Lyon 1 (UCBL), Université de Lyon-Université de Lyon-Institut National de Recherche en Informatique et en Automatique (Inria)-Centre National de la Recherche Scientifique (CNRS), Institut de recherche en informatique de Toulouse (IRIT), Université Toulouse Capitole (UT Capitole), Université de Toulouse (UT)-Université de Toulouse (UT)-Université Toulouse - Jean Jaurès (UT2J), Université de Toulouse (UT)-Université Toulouse III - Paul Sabatier (UT3), Université de Toulouse (UT)-Centre National de la Recherche Scientifique (CNRS)-Institut National Polytechnique (Toulouse) (Toulouse INP), Université de Toulouse (UT)-Toulouse Mind & Brain Institut (TMBI), Université Toulouse - Jean Jaurès (UT2J), Université de Toulouse (UT)-Université de Toulouse (UT)-Université Toulouse III - Paul Sabatier (UT3), Université de Toulouse (UT), Algorithms and Software Architectures for Distributed and HPC Platforms (AVALON), Inria Grenoble - Rhône-Alpes, Institut National de Recherche en Informatique et en Automatique (Inria)-Institut National de Recherche en Informatique et en Automatique (Inria)-Laboratoire de l'Informatique du Parallélisme (LIP), Université de Lyon-Université de Lyon-Institut National de Recherche en Informatique et en Automatique (Inria)-Centre National de la Recherche Scientifique (CNRS)-École normale supérieure de Lyon (ENS de Lyon)-Université Claude Bernard Lyon 1 (UCBL), Université de Lyon-Université de Lyon-Centre National de la Recherche Scientifique (CNRS), Université de Lyon, Laurent Lefèvre, Jean-Marc Pierson, Centre National de la Recherche Scientifique (CNRS)-Université de Lyon-Institut National de Recherche en Informatique et en Automatique (Inria)-Université Claude Bernard Lyon 1 (UCBL), Université de Lyon-École normale supérieure - Lyon (ENS Lyon), Université Toulouse 1 Capitole (UT1), Université Fédérale Toulouse Midi-Pyrénées-Université Fédérale Toulouse Midi-Pyrénées-Université Toulouse - Jean Jaurès (UT2J)-Université Toulouse III - Paul Sabatier (UT3), Université Fédérale Toulouse Midi-Pyrénées-Centre National de la Recherche Scientifique (CNRS)-Institut National Polytechnique (Toulouse) (Toulouse INP), Université Fédérale Toulouse Midi-Pyrénées, Université de Lyon-École normale supérieure - Lyon (ENS Lyon)-Centre National de la Recherche Scientifique (CNRS)-Université de Lyon-Université Claude Bernard Lyon 1 (UCBL)
Jazyk: angličtina
Rok vydání: 2016
Předmět:
Zdroj: Distributed, Parallel, and Cluster Computing [cs.DC]. Université de Lyon, 2016. English. ⟨NNT : 2016LYSEN057⟩
Popis: The increasing number of data centers raises serious concerns regarding their energy consumption. These infrastructures are often over-provisioned and contain servers that are not fully utilized. The problem is that inactive servers can consume as high as 50% of their peak power consumption.This thesis proposes a novel approach for building data centers so that their energy consumption is proportional to the actual load. We propose an original infrastructure named BML for "Big, Medium, Little", composed of heterogeneous computing resources : from low power processors to classical servers. The idea is to take advantage of their different characteristics in terms of energy consumption, performance, and switch on reactivity to adjust the composition of the infrastructure according to the load evolutions. We define a generic methodology to compute the most energy proportional combinations of machines based on hardware profiling data.We focus on web applications whose load varies over time and design a scheduler that dynamically reconfigures the infrastructure, with application migrations and machines switch on and off, to minimize the infrastructure energy consumption according to the current application requirements.We have developed two different dynamic provisioning algorithms which take into account the time and energy overheads of the different reconfiguration actions in the decision process. We demonstrate through simulations based on experimentally acquired hardware profiles that we achieve important energy savings compared to classical data center infrastructures and management.; La consommation énergétique des centres de calculs et de données, aussi appelés « data centers », représentait 2% de la consommation mondiale d'électricité en 2012. Leur nombre est en augmentation et suit l'évolution croissante des objets connectés, services, applications, et des données collectées. Ces infrastructures, très consommatrices en énergie, sont souvent sur-dimensionnées et les serveurs en permanence allumés. Quand la charge de travail est faible, l'électricité consommée par les serveurs inutilisés est gaspillée, et un serveur inactif peut consommer jusqu'à la moitié de sa consommation maximale. Cette thèse s'attaque à ce problème en concevant un data center ayant une consommation énergétique proportionnelle à sa charge. Nous proposons un data center hétérogène, nommé BML pour « Big, Medium, Little », composé de plusieurs types de machines : des processeurs très basse consommation et des serveurs classiques. L'idée est de profiter de leurs différentes caractéristiques de performance, consommation, et réactivité d'allumage, pour adapter dynamiquement la composition de l'infrastructure aux évolutions de charge. Nous décrivons une méthode générique pour calculer les combinaisons de machines les plus énergétiquement efficaces à partir de données de profilage de performance et d'énergie acquis expérimentalement considérant une application cible, ayant une charge variable au cours du temps, dans notre cas un serveur web.Nous avons développé deux algorithmes prenant des décisions de reconfiguration de l'infrastructure et de placement des instances de l'application en fonction de la charge future. Les différentes temporalités des actions de reconfiguration ainsi que leur coûts énergétiques sont pris en compte dans le processus de décision. Nous montrons par simulations que nous atteignons une consommation proportionnelle à la charge, et faisons d'importantes économies d'énergie par rapport aux gestions classiques des data centers.
Databáze: OpenAIRE