Nylon clamp as an alternative hemostatic method compared to surgical nylon suture in bitches ovariosalpingohisterectomy

Autor: da Silva, Walnilson Mota, Guimarães, Jose Eugênio, Filho, Emanuel F. Martins, Filho, Carlos Humberto Almeida Ribeiro, Bastos, Bruno Lopes, Resende, Letícia Santos, Ferreira, Ana Raquel de Araújo, Quesada, Ana Maria, Neto, João Moreira da Costa
Jazyk: portugalština
Rok vydání: 2016
Předmět:
Zdroj: Brazilian Journal of Veterinary Medicine; Vol. 38 No. Supl. 1 (2016); 173-179
Revista Brasileira de Medicina Veterinária; v. 38 n. Supl. 1 (2016); 173-179
Revista Scientific; Vol. 3 No. 10 (2018): Revista Scientific; 95-114
Revista Scientific; Vol. 3 Núm. 10 (2018): Revista Scientific; 95-114
Brazilian Journal of Veterinary Medicine
Sociedade de Medicina Veterinária do Estado do Rio de Janeiro (SOMVERJ)
instacron:SBMV
Revista Scientific; Vol 3 No 10 (2018): Revista Scientific; 95-114
ISSN: 2527-2179
0100-2430
2542-2987
Popis: da Silva W.M., Guimarães J.E., Martins Filho E.F., Ribeiro Filho C.H.A., Bastos B.L., Resende L.S., Ferreira A.R. de A., Quesada A.M. & Costa Neto J.M. [Nylon clamp as an alternative hemostatic method compared to surgical nylon suture in bitches ovariosalpingohisterectomy.] Braçadeira de náilon como método hemostático alternativo em comparação com o fio de náilon cirúrgico na ovariosalpingohisterectomia de cadelas. Revista Brasileira de Medicina Veterinária, 38(Supl.1):173-179, 2016. Programa de Pós-Graduação Ciência Animal nos Trópicos, Universidade Federal da Bahia, Av. Ademar de Barros, 500, Ondina, Salvador, BA 40170-110, Brasil. E-mail: jmcn@ufba.br In order to evaluate the effectiveness of the nylon tie strap as hemostatic method in ovariohysterectomy in bitches as compared to conventional ligature with surgical nylon, was measured up the inflammatory response resulting from surgical trauma, through the evaluation of white blood cells count and dosage of C-reactive protein, haptoglobin and ceruloplasmin. Were used 14 healthy and anestrous bitches, distributed into two groups of equal number: nylon tie strap group (GB) and nylon group (GN). The obliteration of the vascular components of the uterus and ovaries was performed in GB with the use of nylon tie straps and group GN with ligatures and surgical nylon. For laboratory analysis, the blood samples were collected before the procedure, immediately after surgery, and at 12, 24, 48, 96, 168 and 240 hours of postoperative observation. During surgery, nylon tie straps similar behavior in the two experimental groups, without consistent changes that would make the techniques impracticable, there was no statistically significant difference (p
Com o objetivo de avaliar o emprego da braçadeira de náilon como método hemostático na ovariosalpingohisterectomia de cadelas em comparação ao método convencional de ligadura com fio de náilon cirúrgico, avaliou-se a segurança, praticidade, e o custo operacional, bem como a resposta inflamatória decorrente do uso destes diferentes materiais, através do leucograma e dosagem da proteína C-reativa, haptoglobina e ceruloplasmina. Foram utilizadas 14 cadelas hígidas em anestro, distribuídas em dois grupos experimentais de igual número: grupo braçadeira (GB) e grupo náilon (GN). A obliteração dos componentes vasculares do útero e ovários foi realizada no GB com uso de braçadeiras de náilon e no grupo GN com uso do fio de náilon cirúrgico. Para análise laboratorial, as amostras de sangue foram coletadas imediatamente antes do procedimento cirúrgico, logo após a cirurgia, e às 12, 24, 48, 96, 168 e 240 horas de observação pós-operatória. No trans-operatório, as braçadeiras mostraram-se de fácil e rápida aplica- ção, conferindo a constrição necessária à técnica hemostática. Comparando-a ao emprego de ligadura com fio de náilon cirúrgico, apresentaram vantagens relativas ao tempo cirúrgico e ao custo dos materiais. O processo inflamatório, mensurado por meio da análise das proteínas de fase aguda e do leucograma, mostrou comportamento semelhante nos dois grupos experimentais, sem alterações consistentes que inviabilizassem as técnicas utilizadas, não havendo diferença estatística significativa (p
Databáze: OpenAIRE