Detección de trazas de soja y de leche en productos libres de gluten: desarrollo de dos enzimoinmunoensayos competitivos
Autor: | Karina Cellerino, María Julieta Binaghi, Vanina Andrea Ambrosi, Laura Beatriz López |
---|---|
Jazyk: | Spanish; Castilian |
Rok vydání: | 2020 |
Předmět: | |
Zdroj: | Acta bioquímica clínica latinoamericana, Volume: 54, Issue: 4, Pages: 395-406, Published: 28 JUL 2020 Redalyc |
Popis: | Resumen El objetivo del presente trabajo fue el desarrollo de dos enzimoinmunoensayos competitivos (EIC) para la detección de trazas de soja y de leche en productos libres de gluten. Como anticuerpos primarios se utilizaron antisueros policlonales de conejo específicos contra proteínas de soja o de leche. Se determinaron las concentraciones óptimas de antígenos a inmovilizar en la placa y las concentraciones de anticuerpos primarios a utilizar en la competencia. Las curvas de calibración se ajustaron utilizando concentraciones crecientes de un extracto de producto de soja y de un extracto de leche descremada en polvo. El producto de soja y la leche descremada se extrajeron con buffer Tris-HCl 0,0625 M con dodecilsulfato de sodio al 3% y sulfito de sodio 0,1 M al 2%. Se evaluaron los parámetros de validación: linealidad, límites de detección y de cuantificación, recuperación y precisión en el día y entre días, los cuales resultaron adecuados. Se analizaron 9 productos libres de gluten con los EIC desarrollados y con kits de ELISA comerciales. Ambos EIC se comportaron de manera similar con respecto a los kits comerciales. Los EIC permitieron confirmar la presencia de leche en las muestras que la declaraban. En algunas muestras que no declaraban ni leche ni soja, ambos EIC detectaron su presencia (resultados confirmados con los kits comerciales). Los EIC desarrollados poseen menor costo que los kits y, por lo tanto, éstos podrían utilizarse como métodos de screening. Cuando esta metodología resulte negativa, debe confirmarse con un método más sensible (comercial) para garantizar la ausencia de proteínas de soja o de leche. Abstract The aim of this study was to develop two competitive enzyme immunoassays (CEI) to detect the presence of traces of soy and milk in gluten-free products. Specific rabbit polyclonal antiserums against soy protein and other against elemilk protein were used as primary antibodies. Optimal antigen concentrations to be immobilized on the plate and primary antibody concentrations to be used in competition were determined. The calibration curves were fitted using increasing concentrations of an extract of soy product and of defatted milk powder. The soy product and the defatted milk were extracted with Tris-HCl buffer 0,0625 M with 3% sodium dodecyl sulfate and 2% sodium sulfite 0.1 M. The validation parameters were evaluated: linearity, limit of detection and quantification, recovery and precision on the day and in between days. They were appropriate. Nine commercial samples of gluten-free products were analyzed with these developed CEI and commercial ELISA kits. It was observed that both CEI behaved similarly with respect to the commercial kits. The enzyme immunoassays confirmed the presence of milk in samples that declared it. In some samples that did not declare the presence of milk or soy, both enzyme immunoassays detected their presence –these results were confirmed using commercial kits. The developed CEI have a lower cost than the commercial kits, so these could be used as screening methods. When this methodology is negative, it should be confirmed with a more sensitive (commercial) method to ensure the absence of soy or milk protein. Resumo O objetivo do presente trabalho foi o desenvolvimento de dois enzimoimunoensaios competitivos (EIC), para a detecção de vestígios de soja e leite em produtos livres de glúten. Antissoros policlonais de coelho específicos contra proteínas de soja ou de leite foram utilizados como anticorpos primários. Foram determinadas as concentrações ótimas de antígenos a serem imobilizados na placa e as concentrações de anticorpos primários a serem utilizadas na competição. As curvas de calibração foram ajustadas usando concentrações crescentes de um extrato de produto de soja e de um extrato de leite em pó desnatado. O produto de soja e o leite desnatado foram extraídos com tampão Tris-HCl 0,0625 M com dodecil sulfato de sódio a 3% e sulfito de sódio 0,1 M a 2%. Os parâmetros de validação foram avaliados: linearidade, limite de detecção e quantificação, recuperação e precisão no dia e entre os dias, os quais resultaram adequados. Nove produtos livres de glúten foram analisados com os EIC desenvolvidos e com kits de ELISA comerciais. Os dois EICs se comportaram de maneira semelhante em relação aos kits comerciais. Os EIC permitiram confirmar a presença de leite nas amostras que o declararam. Em algumas amostras que declaravam nem leite nem soja, ambos os EIC detectaram sua presença (resultados confirmados usando kits comerciais). Os EIC desenvolvidos têm um custo menor que os kits, portanto, eles poderiam ser utilizados como métodos de triagem. Quando esta metodologia é negativa, deve ser confirmada com um método mais sensível (comercial) para garantir a ausência de proteínasda soja ou do leite. |
Databáze: | OpenAIRE |
Externí odkaz: |