Estimating fetal dose from tube current-modulated (TCM) and fixed tube current (FTC) abdominal/pelvis CT examinations

Autor: Hardy, Anthony J, Angel, Erin, Bostani, Maryam, Cagnon, Chris, McNitt-Gray, Michael
Rok vydání: 2019
Předmět:
Zdroj: Medical physics, vol 46, iss 6
Popis: PurposeThe purpose of this work was to estimate scanner-independent CTDIvol -to-fetal-dose coefficients for tube current-modulated (TCM) and fixed tube current (FTC) computed tomography (CT) examinations of pregnant patients of various gestational ages undergoing abdominal/pelvic CT examinations.MethodsFor 24 pregnant patients of gestational age from
Databáze: OpenAIRE