Three-dimensional assessment of curvature, torsion, and canal flare index of the humerus of skeletally mature nonchondrodystrophic dogs
Autor: | Smith, Emily J, Marcellin-Little, Denis J, Harrysson, Ola LA, Griffith, Emily H |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2017 |
Předmět: | |
Zdroj: | Smith, EJ; Marcellin-Little, DJ; Harrysson, OLA; & Griffith, EH. (2017). Three-dimensional assessment of curvature, torsion, and canal flare index of the humerus of skeletally mature nonchondrodystrophic dogs. American Journal of Veterinary Research, 78(10), 1140-1149. doi: 10.2460/ajvr.78.10.1140. UC Davis: Retrieved from: http://www.escholarship.org/uc/item/5d91x350 American journal of veterinary research, vol 78, iss 10 |
DOI: | 10.2460/ajvr.78.10.1140. |
Popis: | © 2017, American Veterinary Medical Association. All rights reserved. OBJECTIVE To assess 3-D geometry of the humerus of dogs and determine whether the craniocaudal canal flare index (CFI) is associated with specific geometric features. SAMPLE CT images (n = 40) and radiographs (38) for 2 groups of skeletally mature nonchondrodystrophic dogs. PROCEDURES General dimensions (length, CFI, cortical thickness, and humeral head off-set), curvature (shaft, humeral head, and glenoid cavity), version (humeral head and greater tubercle), and torsion were evaluated on CT images. Dogs were allocated into 3 groups on the basis of the craniocaudal CFI, and results were compared among these 3 groups. The CT measurements were compared with radiographic measurements obtained for another group of dogs. RESULTS Mean ± SD humeral head version was –75.9 ± 9.6° (range, –100.7° to –59.4°). Mean mechanical lateral distal humeral angle, mechanical caudal proximal humeral angle, and mechanical cranial distal humeral angle were 89.5 ± 3.5°, 50.2 ± 4.5°, and 72.9 ± 7.8°, respectively, and did not differ from corresponding radiographic measurements. Mean humeral curvature was 20.4 ± 4.4° (range, 9.6° to 30.5°). Mean craniocaudal CFI was 1.74 ± 0.18 (range, 1.37 to 2.10). Dogs with a high craniocaudal CFI had thicker cranial and medial cortices than dogs with a low craniocaudal CFI. Increased body weight was associated with a lower craniocaudal CFI. Radiographic and CT measurements of craniocaudal CFI and curvature differed significantly. CONCLUSIONS AND CLINICAL RELEVANCE CT-based 3-D reconstructions allowed the assessment of shaft angulation, torsion, and CFI. Radiographic and CT measurements of shaft curvature and CFI may differ. |
Databáze: | OpenAIRE |
Externí odkaz: |