Is spectral domain optical coherence tomography useful in improving the contour line with the heidelberg retina tomograph?
Autor: | Bron , Alain M., Francoz , Anna, Nicot , Frédéric, Aho , Serge, Acar , Niyazi, Bretillon , Lionel, Creuzot Garcher , Catherine |
---|---|
Přispěvatelé: | Service d'Ophtalmologie (CHU de Dijon), Centre Hospitalier Universitaire de Dijon - Hôpital François Mitterrand (CHU Dijon), Epidemiology, Centre des Sciences du Goût et de l'Alimentation [Dijon] (CSGA), Centre National de la Recherche Scientifique (CNRS)-AgroSup Dijon - Institut National Supérieur des Sciences Agronomiques, de l'Alimentation et de l'Environnement-Institut National de la Recherche Agronomique (INRA)-Université de Bourgogne (UB), Institut National de la Recherche Agronomique (INRA)-Université de Bourgogne (UB)-AgroSup Dijon - Institut National Supérieur des Sciences Agronomiques, de l'Alimentation et de l'Environnement-Centre National de la Recherche Scientifique (CNRS), ProdInra, Archive Ouverte, Centre Hospitalier Universitaire de Dijon - Hôpital François Mitterrand ( CHU Dijon ), Centre des Sciences du Goût et de l'Alimentation [Dijon] ( CSGA ), Institut National de la Recherche Agronomique ( INRA ) -Université de Bourgogne ( UB ) -AgroSup Dijon - Institut National Supérieur des Sciences Agronomiques, de l'Alimentation et de l'Environnement-Centre National de la Recherche Scientifique ( CNRS ) |
Jazyk: | angličtina |
Rok vydání: | 2012 |
Předmět: |
ICG
FA genetic structures [ SDV.AEN ] Life Sciences [q-bio]/Food and Nutrition rétine 624 optic disc SLO tomography eye diseases tomographie [SDV.AEN] Life Sciences [q-bio]/Food and Nutrition ultrasound) RTA OCT [SDV.MHEP.OS] Life Sciences [q-bio]/Human health and pathology/Sensory Organs 549 imaging/image analysis: clinical 551 imaging methods (CT [ SDV.MHEP.OS ] Life Sciences [q-bio]/Human health and pathology/Sensory Organs sense organs [SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory Organs [SDV.AEN]Life Sciences [q-bio]/Food and Nutrition MRI |
Zdroj: | annual meeting of the association-for-research-in-vision-and-ophthalmology (ARVO) annual meeting of the association-for-research-in-vision-and-ophthalmology (ARVO), May 2012, Fort Lauderdale, Floride, United States. Association for Research in Vision and Ophthalmology, Investigative Ophthalmology and Visual Science, 53, 1 p., 2012, Investigative Ophthalmology and Visual Science annual meeting of the association-for-research-in-vision-and-ophthalmology (ARVO), May 2012, Fort Lauderdale, Floride, United States. Association for Research in Vision and Ophthalmology, 53, 1 p., 2012, Investigative Ophthalmology and Visual Science |
Popis: | Purpose: To compare the measurements of the optic disc in glaucoma patients and glaucoma suspects with spectral domain optical coherence tomography (SD-OCT) and confocal scanning laser ophthalmoscopy (HRT) before and after adjustment of the contour line with the help of the OCT.Methods: In 109 consecutive patients (109 eyes), optic disc parameters were compared prospectively between the 2 devices before and after adjustment of the optic disc area (ODA) on the HRT3 with ODA obtained with the Cirrus SD-OCT as a reference. Intraclass correlation coefficients (ICC) and the 95% limits of agreement (LoA) with Bland-Altman plots were used to compare the agreement of the pre and post-adjustment measurements with the OCT and the HRT.Results: The ICC for the optic disc area (ODA) was better after adjustment of the contour line on the HRT3 with the help of ODA obtained with the OCT, 0.785 and 0.985, respectively. However the ICC for the rim area (RA) was still moderate after the adjustment, 0.543 and 0.627 respectively. Other parameters C/D ratio, cup area and cup volume were almost unchanged. The 95% limits of agreement (LoA) with Bland-Altman analysis were narrowed after the adjustment of the ODA, from -0.52 to + 0.71 mm2 to -0.12 to + 0.15 mm2. However the LoA remained wide for the RA even after correction of the contour line on the HRT with the help of the OCT, -0.32 to + 0.74 mm2 vs -0.23 to +0.61 mm2.Conclusions: SD-OCT is an additional valuable tool in improving the placement of the contour line on the HRT. However the parameters of the optic disc measured by the 2 methods are not interchangeable. |
Databáze: | OpenAIRE |
Externí odkaz: |