Autor: |
J. de Boer, Waldo, van der Voet, Hilko, G. de Ruig, Wil, A. (Hans) van Rhijn, J., M. Cooper, Kevin, Glenn Kennedy, D., K. P. Patel, Raj, Porter, Sharon, Reuvers, Thea, Marcos, Victoria, Muñoz, Patricia, Bosch, Jaume, Rodríguez, Pilar, M. Grases, Josep |
Zdroj: |
Analyst; February 1, 1999, Vol. 124 Issue: 2 p109-114, 6p |
Abstrakt: |
GC-MS data on veterinary drug residues in bovine urine are used for controlling the illegal practice of fattening cattle. According to current detection criteria, peak patterns of preferably four ions should agree within 10 or 20% from a corresponding standard pattern. These criteria are rigid, rather arbitrary and do not match daily practice. A new model, based on multivariate modeling of log peak abundance ratios, provides a theoretical basis for the identification of analytes and optimizes the balance between the avoidance of false positives and false negatives. The performance of the model is demonstrated on data provided by five laboratories, each supplying GC-MS measurements on the detection of clenbuterol, dienestrol and 19β-nortestosterone in urine. The proposed model shows a better performance than confirmation by using the current criteria and provides a statistical basis for inspection criteria in terms of error probabilities. |