The Effect of a Mediastinal Mass on the Initial Positioning of a Peripherally Inserted Central Venous Catheter

Autor: Tamburro, Robert F., Conner, David T., Proctor, Kimberly E., Butler, Cheryl L., Britton, Lunetha R.
Zdroj: Journal of Infusion Nursing; March 2003, Vol. 26 Issue: 2 p92-96, 5p
Abstrakt: The purpose of this project was to assess if the presence of a mediastinal mass adversely influences peripherally inserted central catheter (PICC) positioning. A retrospective review of all PICC placements over an 18-month period in a pediatric oncology hospital was conducted in which patients were categorized by the presence or absence of a mediastinal mass. A much higher proportion of patients with a mediastinal mass (8 of 13) had a malpositioned catheter than those without a mass (3 of 38;P .0002). A significant proportion of the malpositioned catheters in patients with a mediastinal mass terminated in the right heart chambers. These findings show that clinicians must be vigilant about checking for PICC malpositioning in this patient population.