Autor: |
Ruggeri, Giulia Maria, Qua Hiansen, Joshua, Pivetta, Emanuele, Mashari, Azad, Ballocca, Flavia, Pinto Ribeiro, Roberto Vanin, Xin, Liming, Badiwala, Mitesh, Thampinathan, Babita, Meineri, Massimiliano |
Zdroj: |
Anesthesia & Analgesia; September 2018, Vol. 127 Issue: 3 pe36-e39, 4p |
Abstrakt: |
Ex vivo heart perfusion (EVHP) is a new technology aimed at decreasing cold ischemia time and evaluating cardiac function before transplanting a donor heart. In an experimental EVHP swine model, we tested a 3D-printed custom-made set-up to perform surface echocardiography on an isolated beating heart during left ventricular loading. The views obtained at any time point were equivalent to standard transesophageal and transthoracic views. A decrease in left ventricular function during EVHP was observed in all experiments. |
Databáze: |
Supplemental Index |
Externí odkaz: |
|