Autor: |
Nain, Sunil, Parinam, Anuradha, Kajal, Sanjay |
Zdroj: |
International Journal of Ambient Energy; February 2018, Vol. 39 Issue: 2 p143-146, 4p |
Abstrakt: |
ABSTRACTAn experimental study of air heating system was carried out using a parabolic trough collector with a U-tube aluminium heat exchanger. An evacuated tube placed at the focal length of the parabolic trough collected the solar radiations reflected from the surface of parabolic trough. The air was used as a working fluid, which was heated by passing it through a U-shaped aluminium heat exchanger placed inside the evacuated tube. It was found that efficiency of the parabolic trough collector depends on the mass flow rate, solar intensity and use of fins. It was observed that by using fins at a high mass flow rate of 4.557 kg/h, the maximum temperature of 126°C was achieved which is 13.27% more than the maximum temperature obtained without fins. Furthermore, for a low-mass-flow rate of 1.69 kg/h, the maximum temperature obtained was 149°C. |
Databáze: |
Supplemental Index |
Externí odkaz: |
|