A Comparison of Erythropoietin∗Bioassays

Autor: DeGowin, Richard L., Hofstra, Diana, Gurney, Clifford W.
Zdroj: Experimental Biology and Medicine; May 1962, Vol. 110 Issue: 1 p48-51, 4p
Abstrakt: The transfused plethoric mouse is sensitive to quantities of erythropoietin as small as 0.05 unit as measured by radioiron administered 2 1/2 days after challenge with the hormone. A sigmoidal curve describes the relationship between incremental log-doses of purified erythropoietin and incorporation of radioiron into circulating red blood cells.