Abstrakt: |
To determine the infection source of a sporadic Legionellapneumonia case associated with a hot spring bath, we used five molecular methods, including repetitive element polymerase chain reaction (rep‐PCR), arbitrarily primed PCR (AP‐PCR), ribotyping, restriction endonuclease analysis (REA), and macrorestriction endonuclease analysis (MREA) by pulsed‐field gel electrophoresis. L. pneumophilaserogroup (SG) 3 strain EY 3702, isolated from an intratracheal specimen of a 71‐year‐old Japanese female who developed pneumonia after nearly drowning in a hot spring spa bath, produced rep‐PCR and AP‐PCR fingerprints identical to those of L. pneumophilaSG 3 strains EY 3768 and EY 3769 isolated from the bath water. Four epidemiologically unrelated L. pneumophilaSG 3 strains showed different rep‐PCR or AP‐PCR fingerprints from those of the three EY strains (EY 3702, 3768, and 3769). The three EY strains were also genotypically indistinguishable by ribotyping with EcoRI and PstI, by REA with EcoBI or HindIII, and by MREA with NotI. Based on these results, we identified the bath water of the hot spring spa as the source of infection of this patient, even though the viable number of the organisms in the bath water was low (3 CFU/100 ml) when determined 27 days after her nearly drowning. |