Abstrakt: |
The mixed arrangement irregular heat-pipe flue gas heat transfer was researched, using numerical simulation method. The irregular heat-pipe: triangle heat pipe; square heat pipe. The heat pipe equivalent diameter of flue gas heat transfer is 20 mm, the speed of inlet flue gas is 11 m/s, the inlet temperature of flue gas is 500 K. the results show mixed arrangement irregular heat-pipe can enhance heat exchanging, the optimal parameters of mixed arrangement structure in the condition of given working condition: the first row is triangle heat pipe, the second row is circular heat pipe, the third row is triangle heat pipe, row 4 is square heat pipe, the line spacing of the first row and second is 40 mm, the line spacing of the second and third row is 40 mm, the line spacing of the third row and the fourth row is 35 mm, and the row spacing of the tube is 40 mm. the heat transfer efficiency of the optimized irregular heat-pipe-exchanger raised 40 ~ 60%. |