Stability of a nuclear power generation plant with circulating fuel

Autor: Goryachenko, V. D.
Zdroj: Atomic Energy; July 1966, Vol. 21 Issue: 1 p613-617, 5p
Abstrakt: A nuclear power plant with circulating incompressible fuel is discussed. The active zone of the reactor is idealized by a system with lumped parameters and the heat exchanger by a unit with distributed parameters. The stability of such a plant over a small region of the steady state cycle of operation is demonstrated. For the special case when the importance of delayed neutrons is negligibly small, the stability is demonstrated relative to arbitrary deviations from the equilibrium state.