Experience in scale-up of homogeneous perfusion culture for hybridomas

Autor: Greenfield, P. F., Guillaume, J. -M., Randerson, D. H., Smith, C. G.
Zdroj: Bioprocess and Biosystems Engineering; June 1991, Vol. 6 Issue: 5 p213-219, 7p
Abstrakt: A perfusion system for production of monoclonal antibodies was developed using an externally-mounted, hollow-fibre cartridge. The experimental apparatus was operated for 420 h and demonstrated increased steady-state viable cell concentration with increase in perfusion rate. Antibody titres were up to three times those measured for batch cultures and specific antibody productivity was doubled.
Databáze: Supplemental Index