Autor: |
Sandrik, James, Kaminski, Edward, Greener, Evan |
Zdroj: |
Artificial Cells, Blood Substitutes, and Biotechnology; 1974, Vol. 2 Issue: 1 p31-39, 9p |
Abstrakt: |
Four commercial nickel-base alloys were implanted in rabbit muscle for periods of 2 to 54 weeks. Biocompatibility and tissue reaction was assessed by histological and histochemical techniques. Results were compared with control implants of AISI Type 316L stainless steel. A prominent and constant feature associated with implanted nickel-base alloys was the histological appearance of adipose tissue surrounding the implant. |