Autor: |
Mariani, Gonzalo, Dik, Pablo Brener, Ezquer, Analía, Aguirre, Adolfo, Esteban, Mirta Lucía, Perez, Cecilia, Jonusas, Silvia Fernandez, Fustiñana, Carlos |
Zdroj: |
Journal of Pediatrics; Apr2007, Vol. 150 Issue 4, p418-421, 4p |
Abstrakt: |
Objective: To determine the pre- and post-ductal oxygen saturation (SpO2) levels during the first minutes after birth in healthy term infants. Study design: In a prospective cohort study, sensors were placed on the right hand and on 1 foot of the neonate. Pre- and post-ductal SpO2 levels were recorded during the first 15 minutes after birth. Exclusion criteria were gestational age <37 weeks, presence of risk factors for asphyxia, emergency cesarean delivery (C/D), congenital anomalies, and multiple pregnancies. Infants who were treated with O2 or positive pressure ventilation were also excluded from the study. Results: The mean (SD) gestational age of the 110 infants was 39 weeks (1.1), and the mean birth weight was 3340 grams (359). At 5 minutes, the mean pre-ductal SpO2 level was 89% (7), and the mean post-ductal SpO2 level was 81% (10). Pre- and post-ductal SpO2 levels were significantly different during the first 15 minutes after birth. The SpO2 level was lower in babies delivered by C/D in comparison to babies born by vaginal delivery. Conclusions: In healthy newly born infants, oxygen saturation rises slowly and does not usually reach 90% in the first 5 minutes of life. A gradient between pre- and post-ductal SpO2 levels remains significant for the first 15 minutes of life. [Copyright &y& Elsevier] |
Databáze: |
Supplemental Index |
Externí odkaz: |
|