Palatal volume and area assessment on digital casts generated from conebeam computed tomography scans.

Autor: Shahen, Shereef, Carrino, Gennaro, Carrino, Rossella, Abdelsalam, Reham, Flores-Mir, Carlos, Perillo, Letizia
Předmět:
Zdroj: Angle Orthodontist; Jul2018, Vol. 88 Issue 4, p397-402, 6p
Abstrakt: Objectives: The objective of this study was to develop a reproducible method to measure the change of palatal volume and area through superimposition using maxillary expansion digital cast models. Materials and Methods: A total of 10 pre- and 10 postexpansion dental cast models were scanned by the same cone-beam computed tomography machine. Superimposition was performed using a fully automated surface-best fit of the palatal surfaces on the digital cast models. A gingival plane, identified only once on superimposed casts, and a distal plane with the lateral closing border and the palatal surface were used to localize this selection of air. Area and volume were calculated for pre- and postexpansion records. Pre- and postexpansion palatal volume and area were measured by the main investigator and three different observers for inter- and intra-observer reproducibility assessment. Results: The level of intra- and inter-observer agreement was very strong (intraclass correlation coefficients ≥ 0.953; P value , .0001) for all measurements. Conclusions: Palatal volume and area measurements based on the proposed superimposition are reproducible and can be used reliably. [ABSTRACT FROM AUTHOR]
Databáze: Supplemental Index