Application of addition-cured silicone denture relining materials to adjust mouthguards.

Autor: Shintaro FUKASAWA, Hiroshi CHUREI, CHOWDHURY, Ruman Uddin, Takahiro SHIRAKO, SHAHRIN, Sharika, SHRESTHA, Abhishekhi, Takahiro WADA, Motohiro UO, Hidekazu TAKAHASHI, Toshiaki UENO
Předmět:
Zdroj: Dental Materials Journal; 2016, Vol. 35 Issue 4, p635-643, 9p
Abstrakt: The purposes of this study were to examine the shock absorption capability of addition-cured silicone denture relining materials and the bonding strength of addition-cured silicone denture relining materials and a commercial mouthguard material to determine its applicability to mouthguard adjustment. Two addition-cured silicone denture relining materials and eleven commercial mouthguard materials were selected as test materials. The impact test was applied by a free-falling steel ball. On the other hand, bonding strength was determined by a delamination test. After prepared surface treatments using acrylic resin on MG sheet surface, 2 types of addition-cured silicone denture relining materials were glued to MG surface. The peak intensity, the time to peak intensity from the onset of the transmitted force and bonding strength were statistically analyzed using ANOVA and Tukey's honest significant difference post hoc test (p<0.05). These results suggest that the silicone denture relining materials could be clinically applicable as a mouthguard adjustment material. [ABSTRACT FROM AUTHOR]
Databáze: Supplemental Index