Abstrakt: |
Severe external hazards on the Japan Sodium-cooled Fast Reactor (JSFR) have been analyzed and evaluated. For seismic design, safety components are confirmed to maintain their functions even against recent strong earthquakes. Integrity of the major components has been confirmed covering recent earthquake conditions. In the case of a tsunami, the seawater pumps for the component cooling water system (CCWS) could be damaged by the tsunami, since they are located at sea level. In the JSFR design with full natural convection decay heat removal systems (DHRSs) and an air-cooling emergency gas turbine, safety-grade components are independent of CCWS, and loss of CCWS does not affect reactor cooling. As a consei-vative case, hypothetical station blackout (SBO) has been evaluated. In the case ofSBO, decay heat is removed by natural convection DHRS, but control of the air cooler (AC) damper is lost after the battery power is out. The analysis has revealed that freezing at one of three ACs could happen due to loss of automatic control of AC dampers. However, the time margin to protected loss of heat sink is evaluated to be >10 days. Manual control of the AC damper is also investigated. Transient analyses show that the AC dampers can be controlled manually adopting a simple operation procedure with sufficient operation time. Decay heat cooling in the case of collapse in all air stacks of AC has been evaluated. The result shows that decay heat could be removed maintaining air paths in two of three ACs by accident management. In conclusion, JSFR in the 2010 design version has enough external hazard toughness mainly thanks to passive safety features and a seismic isolation system. [ABSTRACT FROM AUTHOR] |