Autor: |
Meinguet, Fabien, Nguyen, Ngac-Ky, Sandulescu, Paul, Kestelyn, Xavier, Semail, Eric |
Zdroj: |
IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society; 2013, p5191-5196, 6p |
Abstrakt: |
Multi-phase machines are known for their fault-tolerant capability. However, star-connected machines have no fault tolerance to inverter switch short-circuit fault. This paper investigates the fault-tolerant operation of an open-end five-phase drive, i.e. a multi-phase machine fed with a dual-inverter supply. Inverter switch short-circuit faults are considered and handled with various degrees of reconfiguration. Theoretical developments and experimental results validate the proposed strategies. [ABSTRACT FROM PUBLISHER] |
Databáze: |
Complementary Index |
Externí odkaz: |
|