Abstrakt: |
Investigations were carried out on glass-epoxy composite specimens with varied fibre orientations (±2° to ±88°), prepared by both braided and filament winding techniques. The experimental strength and stiffness of these composites while exhibiting similar trends, correlated well with those predicted by classical laminate theory. The filament wound composites exhibited (20–40%) initial higher properties vis-a-vis the braided composites, while a correlation index between the experimental and theoretical values has been evolved. [ABSTRACT FROM AUTHOR] |