Autor: |
Yu Song, Four, Aurélien, Baudouy, Bertrand |
Předmět: |
|
Zdroj: |
AIP Conference Proceedings; Jan2014, Vol. 1573, p1483-1489, 7p, 1 Diagram, 4 Graphs |
Abstrakt: |
Heat transfer of helium I in a natural circulation loop is experimentally studied around atmospheric pressure. The test section of the loop has an inner diameter of 4 mm and a height of 23 cm and can be uniformly heated by wire heater. On top of the loop, a condenser is mounted and thermally connected to the second-stage of a 1.5 W at 4.2 K GM cryocooler. Helium can be recondensed in the condenser, where the pressure is regulated around the atmospheric pressure. While the dissipated heat flux is increased from 0 to 1 W, one encounters the different heat transfer regimes as single phase liquid convection, two phase nucleate boiling and single phase vapor convection. The wall superheat varies up to 11 K in the single phase vapor convection regime. The wall temperature measurement allows obtaining the boiling curve and determining the heat transfer coefficient. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|