Autor: |
Yücel, Ali Çağın, Gürel, Melek, Güler, Eda, Karabucak, Bekir |
Předmět: |
|
Zdroj: |
Australian Endodontic Journal; Dec2013, Vol. 39 Issue 3, p116-121, 6p |
Abstrakt: |
The aim of this study was to compare new irrigation systems with a conventional irrigation technique for the removal of inter-appointment calcium hydroxide [Ca(OH)2]. Forty-seven extracted human single-rooted teeth were instrumented, and Ca(OH)2 paste was placed into root canals by using a lentulo spiral at the apical third. Teeth were randomly divided into three groups according to different irrigation protocols using a 30-gauge slot-tipped needle, EndoVac system and ProUltra® PiezoFlow™ ultrasonic irrigation system. Scanning electron microscopic images of the selected root canal surfaces (cervical, middle and apical third) were evaluated using a 5-grade scale. The influence of the irrigation system was evaluated using a two-way analysis of variance test and Tukey's test. The EndoVac and PiezoFlow groups demonstrated the lowest scale values (cleanest canals); however, there was no statistical difference between these two groups. The conventional irrigation group exhibited significantly higher scores ( P < 0.05). The conventional needle irrigation was not sufficient to remove Ca(OH)2 from the root canal system. Irrigation with EndoVac and PiezoFlow™ ultrasonic irrigation systems improved the removal of the intracanal medicament resulting in cleaner root canal walls. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|