Autor: |
Omar, MH, Rahman, HA, Majid, MS, Rosmin, N, Hassan, MY, Omar, WZ Wan |
Předmět: |
|
Zdroj: |
Lighting Research & Technology; Dec2013, Vol. 45 Issue 6, p729-739, 11p |
Abstrakt: |
A novel method of reducing the energy consumption of street lighting using electronic ballasts was simulated on 277 units of 250 W high pressure sodium (HPS) street lights for a month. The design of the electronic ballast is detailed. A control system was utilised to dim the lights at hours of reduced traffic. The energy consumption was compared to that of the conventional system. The electronic ballast operates at a higher frequency and corrects any power distortion in the supply. Together with the light dimming capability, the electronic ballast increased the efficiency of the lighting system resulting in a monthly saving of 10.7 MWh, giving a monthly equivalent carbon dioxide reduction of 6.1 tonnes. In Malaysia, this would translate to a monthly cost saving of 37.7%. [ABSTRACT FROM PUBLISHER] |
Databáze: |
Complementary Index |