Autor: |
Rovang, Dean, Welch, Dale, Ives, Harry, Johnson, David L., Kincy, Mark, Lesch, Benny, Maenchen, John, Menge, Peter, Molina, Isidro, Oliver, Bryan, Olson, Craig, Swenson, Chuck, VanDeValde, David |
Předmět: |
|
Zdroj: |
AIP Conference Proceedings; 2002, Vol. 650 Issue 1, p127, 4p |
Abstrakt: |
Sandia National Laboratories is investigating and developing high-dose, high-brightness flash radiographic sources. We are in the process of designing; fabricating and conducting engineering tests on the next-generation magnetically immersed electron diodes. These diodes employ unique, large-bore (80-110 mm), high-field (28-45 T), cryogenically-cooled solenoid magnets to help produce an intense electron beam from a needle-like cathode "immersed" in the strong B[sub z] field of the magnet. The diode designs and status of the engineering development are described. Later this year we plan to conduct experiments with these sources on the new Radiographic Integrated Test Stand (PITS), now in operation at Sandia. In its present three-stage configuration, PITS provides a 4-MV, 150-kA, 70-ns pulse to the diode. Fully three-dimensional particle in cell LSP code simulations are used to investigate relevant physics issues and the expected radiographic performance (spot size and dose) of this system. Preliminary results from these simulations are described. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|