Autor: |
Caldwell, J., Shakibi, B., Moles, M., Sinclair, A. N. |
Předmět: |
|
Zdroj: |
AIP Conference Proceedings; Jan2013, Vol. 1511 Issue 1, p879-886, 8p, 1 Color Photograph, 1 Diagram, 2 Charts, 6 Graphs |
Abstrakt: |
Phased array inspection was conducted on a V-butt welded steel sample with multiple shallow flaws of varying depths. The inspection measurements were processed using Wiener filtering and Autoregressive Spectral Extrapolation (AS) to enhance the signals. Phased array inspections were conducted using multiple phased array probes of varying nominal central frequencies (2.25, 4, 5 and 10 MHz). This paper describes the measured results, which show high accuracy, typically in the range of 0.1-0.2 mm. The results concluded that: 1. There was no statistical difference between the calculated flaw depths from phased array inspections at different flaw tip angles. 2. There was no statistical difference in flaw depths calculated using phased array data collected from either side of the weld. 3. Flaws with depths less than the estimated probe signal shear wavelength could not be sized. 4. Finally, there was no statistical difference in the calculated flaw depths using phased array probes with different sampling frequencies and destructive measurements of the flaws. [ABSTRACT FROM AUTHOR] |