Modeling of domain structure and anisotropy in glass-covered amorphous wires.

Autor: Menard, D., Frankland, D., Ciureanu, P., Yelon, A., Rouabhi, M., Cochrane, R.W., Chiriac, H., Ovari, T.A.
Předmět:
Zdroj: Journal of Applied Physics; 6/1/1998 Part 2 of 2, Vol. 83 Issue 11, p6566, 3p, 1 Chart, 5 Graphs
Abstrakt: Studies by means of giant magnetoimpedance (GMI) at 10 Megahertz and longitudinal magnetization curves, the anisotropy of Co68.15Fe4.35Si12.5B15 wires, glass-covered and after glass removal. What causes the anisotopy in soft amorphous magnetic wires; Comparison of high resolution GMI and magnetometry; Demonstration of hysteresis curves for the amorphous glass-covered wires and wires after glass removal.
Databáze: Complementary Index