Autor: |
Tisseur, D., Buyens, F., Rattoni, B., Cattiaux, G., Sollier, T. |
Předmět: |
|
Zdroj: |
AIP Conference Proceedings; 5/18/2012, Vol. 1430 Issue 1, p613-620, 8p, 2 Diagrams, 1 Chart, 5 Graphs |
Abstrakt: |
The French Institute for Radioprotection and Nuclear Safety (IRSN) in partnership with CEA, has started in 2009 a program over several years for the validation of CIVA RX module. The aim of this paper is to present preliminary results of CIVA RX tools validation. The study consists in a cross comparison between experimental and simulation results. These have been carried out on different objects (step wedge, dissimilar metal weld mock up, IQI, notches) with different sources (Co60 and 450 kV X-ray tube) and radiographic film. Simulation and experimental data are compared in term of optical density, IQI perceptivity and flaws detectability. This study shows a good agreement between experiment and simulation. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|