Autor: |
Moberg, Lars-erik, Köndell, Per-åke, Kullman, Leif, Heimdahl, Anders, Gynther, Göran W. |
Předmět: |
|
Zdroj: |
Clinical Oral Implants Research; Feb1999, Vol. 10 Issue 1, p45-53, 9p |
Abstrakt: |
From January 1992 to March 1997, a total of 30 ITI hollow cylinder implants were installed to replace lost single maxillary incisor teeth. Conical abutments with cemented all-ceramic crowns were used in 10 cases and the Octa-abutment with screw-retained metallo-ceramic crowns in 19 cases. One implant failed due to postoperative infection, and was extracted a month after installation. After a mean observation time of 3.4 years, the cumulative success rate is 96.7%. Only minor bone loss has occurred around the implants, and there have been no other complications to date. The implant system fulfills the requirements for good function 1 and esthetics. [ABSTRACT FROM AUTHOR] |