Autor: |
Fox, J., Prabhakar, S., Teytelman, D., Young, A., Stover, G., Drago, A., Serio, M., Khan, S., Knuth, T., Kim, Y., Park, M. |
Předmět: |
|
Zdroj: |
AIP Conference Proceedings; 2000, Vol. 546 Issue 1, p226, 8p |
Abstrakt: |
A longitudinal instability control system, originally developed for the PEPII, DAΦNE and ALS machines has in the last two years been commissioned for use at the PLS and BESSY-II light sources. All of the installations are running identical hardware and use a common software distribution package. This common structure is beneficial in sharing expertise among the labs, and allows rapid commissioning of each new installation based on well-understood diagnostic and operational techniques. While the installations share the common instability control system, there are significant differences in machine dynamics between the various colliders and light sources. These differences require careful specification of the feedback algorithm and system configuration at each installation to achieve good instability control and useful operational margins. This paper highlights some of the operational experience at each installation, using measurements from each facility to illustrate the challenges unique to each machine. Our experience on the opportunities and headaches of sharing development and operational expertise among labs on three continents is also offered. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |