Autor: |
Bellintani, V., Galva˜o, R. M. O., Vannucci, A., Vuolo, J. H., Ruchko, L., Nascimento, I. C., Elizondo, J. I., Lin, L., Juni, M., Tavares, P. F., Callejas, R. L. |
Předmět: |
|
Zdroj: |
AIP Conference Proceedings; 2001, Vol. 563 Issue 1, p161, 6p, 1 Black and White Photograph, 1 Diagram, 6 Graphs |
Abstrakt: |
A new bolometric calibration for the bolometer that will be used in TCABR tokamak was carried out using the synchrotron light source from LNLS x-ray line. The value of thermal capacity obtained is less than that obtained for the same sensor, when calibrated for use in JET. Preliminary data acquisition in TCABR shows that irradiated power amounts to less then 10% of ohmically input power during current flat top. [ABSTRACT FROM AUTHOR] |
Databáze: |
Complementary Index |
Externí odkaz: |
|